Hi OPAL developers,

In MAD and Bmad, the convention of a tilted bend is to rotate the coordinates at the beginning, and the exit, of a horizontal bend. The result is that a purely vertical bend will keep the ‘y’ axis pointing in the same plane. This is also consistent with how other elements are tracked: a tilted quad does not tilt the pipe downstream. 

In OPAL-T, it seems that the rotation (set by ‘psi’) is at the beginning of the bend, but not undone. Is it possible to make this more in line with MAD and Bmad? 