Hi Andreas,
  I did not get an answer for item 3 but it seems to me that OPAL defacto assumes the emitting surface (injected particles) is at z=0. It allows only for transverse and time offset right now. Best, -- Philippe.

On Sun, Feb 9, 2020, 7:06 PM Adelmann Andreas (PSI) <andreas.adelmann AT psi.ch> wrote:
Dear Philippe did you get an answer ?


Cheers A
------
Dr. sc. math. Andreas (Andy) Adelmann
Head a.i. Labor for Scientific Computing and Modelling 
Paul Scherrer Institut OHSA/ CH-5232 Villigen PSI
Phone Office: xx41 56 310 42 33 Fax: xx41 56 310 31 91
Phone Home: xx41 62 891 91 44
-------------------------------------------------------
Friday: ETH HPK G 28   +41 44 633 3076
============================================
The more exotic, the more abstract the knowledge, 
the more profound will be its consequences.
Leon Lederman 
============================================

On 22 Jan 2020, at 13:35, Philippe Piot <piot AT nicadd.niu.edu> wrote:

Dear All,
  Thank for the answer to my items 2, and 4 below. 
  - Regarding 1, I noticed that my simulation works if I turn off AUTOPHASE (set AUTOPHASE=0 instead of =4) and phase the cavity manually so the hanging seems to be due to the auto-phasing routine somehow.
  - Regarding 3, I would appreciate if somebody has good advice on how to emit a particle from an arbitrary location. It seems the emission mode is only for z=0 (so the cathode by convention is always located at z=0?). Related to this item, I also find in the manual there is a SOURCE element (sec. 6.4) but I am confused about its use or relevance and I could not find any mention of this element anywhere else (I try adding it in my simulation but it did not change anything as far as I can tell). 

  All the best,  -- Philippe. 
 

On Mon, Jan 20, 2020 at 5:56 AM Philippe Piot <piot AT nicadd.niu.edu> wrote:
Dear All,
  I would like to track the dark current (field-)emitted from the wall of an RF gun. As a first simplified approach, I would like to emit a few particles from different sites (on the cavity wall) and follow their trajectories.
  I have a few issues and I hope somebody can make some suggestions:

-1  I prepared a SuperFISH field-map that contains the field inside the cavity (instead of just the paraxial region as usually done) -- the header of the map is:
"
2DDynamic XZ
0.0 66.5  1330
199.6043527245878
0.0 30.0  620
"
OPAL starts and hangs on the map it stops after displaying 
Ippl{0}> * ************* G U N *********   
it does not terminate but just hands and I decided to ctrl+C after 15 mins...  Is there a limit on the map size? The same map dumped over the paraxial region  (header of the map is 
"
2DDynamic XZ
0. 30. 600
199.6043527245878
0. 5. 50
")
works fine (so my fields are OK) and it takes only a few seconds to run OPAL on my laptop (CentOS 8.1).

-2 how do I turn off space charge? I would have thought that just setting the bunch charge to zero would do the trick. But if set the charge to zero and reduce the number of particles to a few 100s, OPAL still cares about the fact that the space-charge mesh size is not set properly (so presumably it is still trying to call the space-charge solver for some reason) 

-3 is the best approach to emitted electron from the cavity wall to set the coordinate/momentum of the particle in the "FROMFILE' type fine? Or can I use another type of distribution?

Finally, I saw OPAL has been used for dark current and multipacting studies https://arxiv.org/abs/1208.6577 .  Are these capabilities still in Opal 2.2? Is there an example file that could be shared?

Thank you very much, -- Philippe.


Philippe Piot,
https://www.niu.edu/advanced-accelerator-randd/
Northern Illinois University, Dept of Physics and
Northern Illinois Center for Accelerator & Detector Development
DeKalb, IL 60115, USA
Tel: 815 753 6473, Web:  http://www.physics.niu.edu/physics/

Argonne National Laboratory, Advanced Photon Source
Accelerator System Division
Lemont, IL 60439, USA
Tel: 630 252 2415, Web:  https://www.aps.anl.gov/Accelerator-Systems-Division 




Archive powered by MHonArc 2.6.19.

Top of Page