Skip to Content.
Sympa Menu

opal - [Opal] VARIABLE_RF_CAVITY in CYCLOTRON-T does not change particle energy

opal AT lists.psi.ch

Subject: The OPAL Discussion Forum

List archive

[Opal] VARIABLE_RF_CAVITY in CYCLOTRON-T does not change particle energy


Chronological Thread  
  • From: 鎌倉恵太 <kamakura AT cns.s.u-tokyo.ac.jp>
  • To: opal AT lists.psi.ch
  • Subject: [Opal] VARIABLE_RF_CAVITY in CYCLOTRON-T does not change particle energy
  • Date: Mon, 25 May 2026 15:20:23 +0900
  • Arc-authentication-results: i=3; mx.microsoft.com 1; spf=pass (sender ip is 2607:f8b0:4864:20::735) smtp.rcpttodomain=lists.psi.ch smtp.mailfrom=cns.s.u-tokyo.ac.jp; dmarc=pass (p=none sp=none pct=100) action=none header.from=cns.s.u-tokyo.ac.jp; dkim=pass (signature was verified) header.d=cns.s.u-tokyo.ac.jp; arc=pass (0 oda=0 ltdi=1)
  • Arc-authentication-results: i=2; mx.microsoft.com 1; spf=pass (sender ip is 2607:f8b0:4864:20::735) smtp.rcpttodomain=lists.psi.ch smtp.mailfrom=cns.s.u-tokyo.ac.jp; dmarc=pass (p=none sp=none pct=100) action=none header.from=cns.s.u-tokyo.ac.jp; dkim=pass (signature was verified) header.d=cns.s.u-tokyo.ac.jp; arc=pass (0 oda=0 ltdi=1)
  • Arc-authentication-results: i=1; mx.google.com; arc=none
  • Arc-message-signature: i=3; a=rsa-sha256; c=relaxed/relaxed; d=microsoft.com; s=arcselector10001; h=From:Date:Subject:Message-ID:Content-Type:MIME-Version:X-MS-Exchange-AntiSpam-MessageData-ChunkCount:X-MS-Exchange-AntiSpam-MessageData-0:X-MS-Exchange-AntiSpam-MessageData-1; bh=MxIb8Wa+cKVkvdvbbQHGaFEI47rxb0A1TFICL5GY9Ic=; b=N5AHw7FompVoY/d7m5f4UHZWtt8eXjAZehmZXiSQhBc6EFvQ/ocIdKDCRRcVwXvVMnbg5yYo0E/N8Z0fCkdgUXEJTQUmQ73XeSysy+/TA8MyUjGSSMnfqmIJ0NQExPmXsP3/qGRD2Aj3mvN3EEc2RM1MQ04MkZZ6ebxevAgGcxhcghiKlxvmX3ByyFHIXYL3HZXh5DgqPXj84jCOoPN23WHIgiJDjEHfBveP6GJkyOSyNKpzJvpkbR8AVwxU2V5sicBQv3uO1elO7u5K02CqujNT8dnYGGgnabuWsoFKkyv1ly9NSzB9bHTt4FzR0++blyu7osKo6MMArACGGNx9Nw==
  • Arc-message-signature: i=2; a=rsa-sha256; c=relaxed/relaxed; d=microsoft.com; s=arcselector10001; h=From:Date:Subject:Message-ID:Content-Type:MIME-Version:X-MS-Exchange-AntiSpam-MessageData-ChunkCount:X-MS-Exchange-AntiSpam-MessageData-0:X-MS-Exchange-AntiSpam-MessageData-1; bh=MxIb8Wa+cKVkvdvbbQHGaFEI47rxb0A1TFICL5GY9Ic=; b=d+VpsS1fAy5oeHYBlsUmsp7CCxm9q6H3U8eycOftTp6Nb9/jWZiTsxWZtMOD3ZLPnhqyS0MnBspHD+V299TiP+0m9j/yDFfIl28Szvr483jvxGz7Lm6/fOUfKVwJ6jcRV5JDWuncH3Rml2RUqLhP5311ootOs1vUogYhs9Rck0nu5siiENCD1ayqcEH7szbtPX5/bPiTM7PVdIdbNdRe7Dnj6+15Fquco8PoZ0b1qFRijItoSrk1L3ew+33fYZ3mqyaeO4BnfsCNe42o9CL7EvUwHLBrEdY3jKdrwbHo1MQx2HlaF3IObwB6ySnVkVB3uoVCdE3ZHNvPJZ7KPM4CMA==
  • Arc-message-signature: i=1; a=rsa-sha256; c=relaxed/relaxed; d=google.com; s=arc-20240605; h=to:subject:message-id:date:from:mime-version:dkim-signature; bh=MxIb8Wa+cKVkvdvbbQHGaFEI47rxb0A1TFICL5GY9Ic=; fh=IBui5IM6DstDBKPr5YNSVmJl+aj6yQNjG3R3pwXEfSw=; b=dqAW/NlFi+NeTYjS03lQwUCHZQ96d7/hACSbnsjjx8vY4kxMIY6CK1twM3eYsgnO4G R42sEYM7fcHxbUFgsJXKgrY9EdLiEv7Mr4E/1O6VVkci/7xyQwlNX6ojuNC5r2ReG+8t qytnqa4FIIZ+JGjOxPgxu3/HB9Vo5wggBKDiktPkKp7SZ0PBWcJ8a3nIsoc6dAMxBDcy ocsD5ZxkCvQDPvUv0Ee6Nny5YBUda2KC+nKaUEZS0KzbOa3yUX9MnlkbuLjW6hxxKK6T 6n/tSRPoCkrfTBUrjcF2oNADgOH8W/FnF5ErPcq6fip6ARtdpuMWYL8ci6NzIsax1lzc kcNg==; darn=lists.psi.ch
  • Arc-seal: i=3; a=rsa-sha256; s=arcselector10001; d=microsoft.com; cv=pass; b=PweDOVshsIWJc+I6r7X4s1LJK9gz4Kc69aRLMuQax4Hwf5I0Y52TNWUvMGxdJYPCYcWmliHbWHK1P0U+R/tKtXFyEqNM6jS+sA4CM4QQqaP7QNFtK7eotuUcrxg3X6QMT7s5RQeJJaojmUw6YVz/+eos4nuCFrzrGG/eH04D0noAY55PtHpgjFtgwgiq3NKEVC9hCGhwTaKvkI/4vRMns6CxdVDOcplNM7SXaWccNAd1ZyAaJ7QFP3Qwm4Qqs8EZjznakIolF1J7SoBAIYdPqo5txXtb6CO8vEhnvhszK22cPcRbaVj0+Yo/RGOmg50+mEfIntlJEs1OBfkRDN+IkA==
  • Arc-seal: i=2; a=rsa-sha256; s=arcselector10001; d=microsoft.com; cv=pass; b=kLduR+qIN7d/zQM6kdO1keg5CvcMSgODiTM0fcYa9+A2F7xp6VM+hkSr0p8uht1S6z0ez9q1npprWQuUE83r5kfPapjyk5TqGtrXOWhdYZC/xs1l+/Bev/STMzacqA2NMNG7YnmbWzvC8EOUvDgl+GGKPyEi4+/gUwmCKlCCvmcb7lX8Kf4PSPKz6YRwlpeMbIVKskJt+Q3chfLBkJzvPO2+WX3mMQbS7dVuh3noXp+4uYvSaoW2LDO4CV23EDLWbJqk4nnHbQzon0OQMyfwM0cPYASLeevDLRn1wgWzMkiXeKc75JLA/Mv0uw7rsx4d9truIBk/42ll/P0LyFj1GA==
  • Arc-seal: i=1; a=rsa-sha256; t=1779690035; cv=none; d=google.com; s=arc-20240605; b=bO50OUE9L+fyoQ59MOajXXwVVQ6KY83TsTMZMNwsdyHvPMTY9BAR77l7Yq6iiWXnhc yFl/9mUUBhcufv8h3MdKH3MutW4GWKAXdCwdw16bgUnMWZW9G+ymvmlqTdhJ0wHraul7 qVs3yWx2/44qzNkU1Q+HWPtUSF2+mPCDbU5dxKbqJbgDlEFLuC96VlveaRvARSnsxmUO IhQZGAMSxRYTts834WWM3PkQq8m6GPs37UaoynIA6NNdU4/6coeu01sgDOvRkClbTfu9 jwP7VS9U4Y5FMikltBLulM2vrDfpF+5SQQiXvWCQlrPuHm7rl2SIHEIgk+sjI3QQqSkz VQ/Q==
  • Authentication-results: spf=pass (sender IP is 2607:f8b0:4864:20::735) smtp.mailfrom=cns.s.u-tokyo.ac.jp; dkim=pass (signature was verified) header.d=cns.s.u-tokyo.ac.jp;dmarc=pass action=none header.from=cns.s.u-tokyo.ac.jp;compauth=pass reason=100

Dear OPAL developers and users,

My name is Keita KAMAKURA, and I work for the University of Tokyo.

I am trying to model a synchrocyclotron in OPAL using CYCLOTRON-T. My magnetic field tracking works with a CYCLOTRON element, but I would like to use VARIABLE_RF_CAVITY to ramp the RF frequency during acceleration.

From the documentation/source/examples, it looks like VARIABLE_RF_CAVITY should be available, and OPAL accepts the input syntax. However, when I include it in a CYCLOTRON-T simulation, the particle energy does not change. The particles continue to track in the magnetic field, but the RF cavity seems to have no accelerating effect.

A simplified version of what I am trying is:

SC: CYCLOTRON,
    FMAPFN="...",
    TYPE="CARBONCYCL",
    RINIT=...,
    PRINIT=0.0,
    PHIINIT=...,
    SYMMETRY=...,
    CYHARMON=1,
    RFFREQ=...;

RFC: VARIABLE_RF_CAVITY,
    VOLT=...,
    FMAPFN="...",
    FREQ=...,
    PHI0=...;

L1: LINE = (SC, RFC);

TRACK, LINE=L1, BEAM=BEAM1,
    MAXSTEPS=...,
    STEPSPERTURN=...;

RUN, METHOD="CYCLOTRON-T",
    BEAM=BEAM1,
    FIELDSOLVER=FS,
    DISTRIBUTION=DIST;
The issue is that the run completes, but the .stat file shows no expected energy gain from the VARIABLE_RF_CAVITY.

I have attached ff_femm_ring.in, which is my current diagnostic input. It combines RINGDEFINITION, VARIABLE_RF_CAVITY, and a CYCLOTRON field map under METHOD="CYCLOTRON-T". OPAL runs this file, but the RF cavity does not appear to affect the particle energy.

My questions are:

Is VARIABLE_RF_CAVITY intended to work with CYCLOTRON-T and CYCLOTRON field-map tracking?
If yes, are there required settings for placement, phase, frequency program, field map format, or RINGDEFINITION that are easy to miss?
If it is accepted by the parser but not applied by CYCLOTRON-T, is this expected behavior or a bug?
What is the recommended way to implement time-dependent RF frequency for a synchrocyclotron in CYCLOTRON-T?
I am using:

OPAL 2024.2
git revision fb396f7b94f3e345534f3af4b69fcb69c7b30272
I would appreciate any advice, examples, or pointers to the relevant part of the code.

Best regards,

Keita Kamakura
--
************************************************
Keita KAMAKURA (鎌倉 恵太)
Project Assistant Professor,
Accelerator Research Division,
Center for Nuclear Study,
The University of Tokyo
TEL:+81-(0)90-6101-6778
************************************************

Attachment: ff_femm_ring.in
Description: Binary data



  • [Opal] VARIABLE_RF_CAVITY in CYCLOTRON-T does not change particle energy, 鎌倉恵太, 05/25/2026

Archive powered by MHonArc 2.6.24.

Top of Page