  • To: <proscan-opinfo-elog AT lists.psi.ch>, "Koenig Stefan (KS07)" <stefan.koenig AT psi.ch>, "Chowdhuri Zema (CZ32)" <zema.chowdhuri AT psi.ch>, "van der Meer Robert (VR17)" <robert.vandermeer AT psi.ch>, "Brinkmann Martin (BA85)" <martin.brinkmann AT psi.ch>, "Veghini Dario Attilio (VD17)" <Dario.Veghini AT psi.ch>
  • Subject: [[Proscan-opinfo-elog] ] ELOG Proscan: Info : Setup
  • Date: Wed, 26 Apr 2017 04:49:15 +0200

Ein neuer ELOG Eintrag wurde eingegeben:

Logbuch : Proscan
Time format WannAutor : Barchetti, Bächli, Vonarburg
Eintrag : Info
Effekt : System : Titel : Setup

Logbuch URL : https://elog-gfa.psi.ch/Proscan/27504

=================================

Das Feld auf 158.95A gestellt statt wie in der Resonanzkurve
bei 158.973A. Der Grund ist die zu hohe Intensität auf dem
PS1 bei der "High" Einstellung. Bei >500nA gibt es eine
Abschaltung. Die Quelle von 160mA auf 140mA reduziert um
die Verluste bei PS1 unter 4000nA zu halten.