Skip to Content.
Sympa Menu

proscan-opinfo-elog - [[Proscan-opinfo-elog] ] ELOG Proscan: Problem Diagnostik & Stopper Strahlweg: MMDC3 Detektorspannung zu klein (MMDV18 Strom zu hoch)

proscan-opinfo-elog AT lists.psi.ch

Subject: Proscan-opinfo-elog mailing list

List archive

[[Proscan-opinfo-elog] ] ELOG Proscan: Problem Diagnostik & Stopper Strahlweg: MMDC3 Detektorspannung zu klein (MMDV18 Strom zu hoch)


Chronological Thread 
  • From: ELog <ELog AT elog-gfa.psi.ch>
  • To: <proscan-opinfo-elog AT lists.psi.ch>, "Koenig Stefan (KS07)" <stefan.koenig AT psi.ch>, "Chowdhuri Zema (CZ32)" <zema.chowdhuri AT psi.ch>, "van der Meer Robert (VR17)" <robert.vandermeer AT psi.ch>, "Brinkmann Martin (BA85)" <martin.brinkmann AT psi.ch>, "Veghini Dario Attilio (VD17)" <Dario.Veghini AT psi.ch>
  • Subject: [[Proscan-opinfo-elog] ] ELOG Proscan: Problem Diagnostik & Stopper Strahlweg: MMDC3 Detektorspannung zu klein (MMDV18 Strom zu hoch)
  • Date: Mon, 26 Jun 2017 14:18:01 +0200

Title: ELOG
Ein neuer ELOG Eintrag wurde eingegeben:
Logbuch: Proscan  Eintrag-ID: 27698    Eingabezeit: Mon 26-Jun-17 14:07
Wann:Mon 26-Jun-17 14:07 
Autor: Dölling 
Eintrag: Problem 
System: Diagnostik & Stopper Strahlweg 
Effekt: anderer 
Titel: MMDC3 Detektorspannung zu klein (MMDV18 Strom zu hoch) 

Spannungsrücklesung MMAC3 und MMAC3A zeigen dass Detektorspannung nur 200 V ist (statt 2000 V).

Der Strom am ISEG-Modul (MMDV18) ist seit 7. Mai erhöht (~900 uA).

Hieraus lässt sich auf defekten Kondensator in Filterplatine I300/T (Bank 2) schliessen.

Filterplatine wurde gewechselt ==> OK

Was fehlt: MMDC3R:ISTB:2 muss ins Logging (alle Minute).

 

 