proscan-opinfo-elog AT lists.psi.ch
Subject: Proscan-opinfo-elog mailing list
List archive
- From: robot <elog-gfa-noreply AT psi.ch>
- To: <proscan-opinfo-elog AT lists.psi.ch>, "Koenig Stefan (KS07)" <stefan.koenig AT psi.ch>, "Chowdhuri Zema (CZ32)" <zema.chowdhuri AT psi.ch>, "van der Meer Robert (VR17)" <robert.vandermeer AT psi.ch>, "Brinkmann Martin (BA85)" <martin.brinkmann AT psi.ch>, "Veghini Dario Attilio (VD17)" <Dario.Veghini AT psi.ch>
- Subject: [[Proscan-opinfo-elog] ] ELOG Proscan: Info : RPS Test Fehler
- Date: Tue, 11 Jul 2017 05:03:24 +0200
bmitted:
Logbuch : Proscan
Time format WannAutor : Ruh, Hottinger, Mäder
Eintrag : Info
Effekt : System : Titel : RPS Test Fehler
Logbuch URL : https://elog-gfa.psi.ch/Proscan/27851
=================================
================== Test 1 =====================
Verify that the differents Modes of the RPS give correct
Outputs on the
RPS module, @ Tue Jul 11 04:59:16 CEST 2017 by nachtschicht
2. set RPS mode for beamline bis BME1: mode to
"2,IQCOM,$BME1,1,DIA"
mode 2,IQCOM,$BME1,1,DIA could not be set -> quit
Interlocks outputs (1-4) of J102003 have the value 0x000C
Interlocks outputs (5-8) of J102003 have the value 0x0000
Info an ZPT
Attachment:
screenshot_15042_1.png
Description: PNG image
- [[Proscan-opinfo-elog] ] ELOG Proscan: Info : RPS Test Fehler, robot, 07/11/2017
- <Possible follow-up(s)>
- [[Proscan-opinfo-elog] ] ELOG Proscan: Info : RPS Test Fehler, robot, 07/12/2017
Archive powered by MHonArc 2.6.19.