Dear developers,

I am using the seed option.
Refering to the manual, SEED=-1 uses the time as seed,
so to my understanding, each run of the same sampler file should
have a different seed and thus different samples.

This doesn't seem to work.
I ran a sampler file twice with SEED=-1 with only one variable.
Each time I start the run, I get identical solenoid settings.

// Sampling methods
SM1: SAMPLING, VARIABLE="sol",  TYPE="UNIFORM",  SEED=-1, RANDOM=TRUE, N=2;

I can work around by setting theseed manually, but that should be fixed, or the manual adapted.
Thank you!

Bettina