Skip to Content.
Sympa Menu

opal - Re: [Opal] OPAL 2.4: Value of AUTOPHASE does not change

opal AT lists.psi.ch

Subject: The OPAL Discussion Forum

List archive

Re: [Opal] OPAL 2.4: Value of AUTOPHASE does not change


Chronological Thread  
  • From: "Adelmann Andreas (PSI)" <andreas.adelmann AT psi.ch>
  • To: Simon Friederich <sifriede AT uni-mainz.de>
  • Cc: "opal AT lists.psi.ch" <opal AT lists.psi.ch>
  • Subject: Re: [Opal] OPAL 2.4: Value of AUTOPHASE does not change
  • Date: Sat, 30 Jan 2021 14:52:51 +0000
  • Accept-language: en-US, de-CH
  • Authentication-results: localhost; iprev=pass (psi-seppmail1.ethz.ch) smtp.remote-ip=129.132.93.141; spf=pass smtp.mailfrom=psi.ch; dmarc=skipped

Hi Simon, I did a quick check AUTOPHASE==0 disables the autophpse procedure and NOT -1 as described in the manual. 
Thanks for pointing that out, will fix the manual.


Cheers A
------
Dr. sc. math. Andreas (Andy) Adelmann
Head a.i. Labor for Scientific Computing and Modelling 
Paul Scherrer Institut OHSA/ CH-5232 Villigen PSI
Phone Office: xx41 56 310 42 33 Fax: xx41 56 310 31 91
Zoom ID: 470-582-4086 Password: AdA
Zoom Link: https://ethz.zoom.us/j/4705824086?pwd=dFcvT1pMMGY0bHg0dTNncUNZZTJkZz09

-------------------------------------------------------
Friday: ETH HPK G 28   +41 44 633 3076
============================================
The more exotic, the more abstract the knowledge, 
the more profound will be its consequences.
Leon Lederman 
============================================

On 28 Jan 2021, at 16:47, Simon Friederich <sifriede AT uni-mainz.de> wrote:

Dear OPAL-Team,

For my purpose I need to make sure, that Autophase is not turned off.
According to the manual (http://amas.web.psi.ch/opal/Documentation/master/OPAL_Manual.html#sec.control.option),
this is the case, if AUTOPHASE = -1.

I realized, that this value is not set and does not differ from the default value 6 though.
test.in

OPTION, AUTOPHASE = -1;
VALUE, OPTION->AUTOPHASE;

OPAL> value: OPTION->AUTOPHASE = {6}

(Same result for different values of AUTOPHASE).

Am I missing something?

Best regards,
Simon

-- 
Dr. Simon Friederich
Helmholtz-Institut Mainz | Insitut für Kernphysik
Kollaboration ACID       | B
Johannes Gutenberg-Universität Mainz
Staudingerweg 18         | Johann-Joachim-Becherweg 45
55128 Mainz, Deutschland

Tel.: +49 (0)6131 39-23160
E-Mail: s.friederich AT uni-mainz.de




Archive powered by MHonArc 2.6.19.

Top of Page