- Ironport-phdr: 9a23:r3EU5RWfmYLfHX0A45xM76JIgPDV8LGtZVwlr6E/grcLSJyIuqrYZhKGt8tkgFKBZ4jH8fUM07OQ6PC8HzVdqsrQ+Fk5M7VyFDY9wf0MmAIhBMPXQWbaF9XNKxIAIcJZSVV+9Gu6O0UGUOz3ZlnVv2HgpWVKQka3CwN5K6zPF5LIiIzvjqbpq8GVOlgD2Gv1SIgxBSv1hD2ZjtMRj4pmJ/R54TryiVwMRd5rw3h1L0mYhRf265T41pdi9yNNp6BprJYYAu2pN5g/GPZfFD0iG2Q0/9Hw8wHYTE2E5jFUBmIOmx5gBwne8Aq8Rozw9CD64LlTwi6faIfWRLJ8ZT2i5r0vADrhjCoEfXZt9WHeiNB5jKtBiBino1pwxJCCM9LdD+Z3Yq6IJYBSfmFGRMsEDyE=
- List-archive: <https://lists.web.psi.ch/pipermail/opal/>
- List-id: The OPAL Discussion Forum <opal.lists.psi.ch>
I believe that the answer lies in the definition of the trace space emittance.
I found a nice paper comparing the development of the normalized emittance and the normalized trace space emittance.
I found a nice paper comparing the development of the normalized emittance and the normalized trace space emittance.
From: Haj Tahar, Malek
Sent: Wednesday, September 09, 2015 2:11 PM
To: opal AT lists.psi.ch
Subject: normalized emittance OPAL
Sent: Wednesday, September 09, 2015 2:11 PM
To: opal AT lists.psi.ch
Subject: normalized emittance OPAL
Dear all,
I have little experience with OPAL and I would like to know if anyone has already encountered this problem: I track a KV beam distribution in an injection line and compute the x-rms emittance which is expected to be constant (since this is a KV beam). Instead, I obtain a strange behavior: when space charge is off, the x-normalized emittance is constant, however, once space charge is on, I have an overshoot in certain locations, specifically at the entrance and exit of some quadrupoles (attached).
I wonder if anyone has an experience with this problem.
Thank you in advance for your help!
I have little experience with OPAL and I would like to know if anyone has already encountered this problem: I track a KV beam distribution in an injection line and compute the x-rms emittance which is expected to be constant (since this is a KV beam). Instead, I obtain a strange behavior: when space charge is off, the x-normalized emittance is constant, however, once space charge is on, I have an overshoot in certain locations, specifically at the entrance and exit of some quadrupoles (attached).
I wonder if anyone has an experience with this problem.
Thank you in advance for your help!
Malek Haj Tahar UJF/BNL
PhD student / ADS-R Group
Brookhaven National Laboratory
Collider Accelerator Department
35 Lawrence Drive, Bldg. 911B, Off. 211
11973 UPTON, NY, USA
Phone: +1 (631)-344-5573
Email: mhajtahar AT bnl.gov
PhD student / ADS-R Group
Brookhaven National Laboratory
Collider Accelerator Department
35 Lawrence Drive, Bldg. 911B, Off. 211
11973 UPTON, NY, USA
Phone: +1 (631)-344-5573
Email: mhajtahar AT bnl.gov