opal AT lists.psi.ch
Subject: The OPAL Discussion Forum
List archive
- From: douguoliang <douguoliang AT impcas.ac.cn>
 - To: opal <opal AT lists.psi.ch>
 - Subject: [Opal] Field Output Command
 - Date: Fri, 4 Mar 2022 11:46:44 +0800
 
        Hi,all
        
After I imported the 3D electric field simulation, I wanted to check whether the electric field read by OPAL and used for calculation was correct. 
I noticed gnu.out and eb.out in the data folder, but the electric field in eb.out was always 0. (attachment 1)
I also tried to modify INFO, TRACE and EBDUMP Option Command, but got no output results. I also notice the DUMPEMFIELDS in the Field output command, but the electric and magnetic fields in output file still are 0.(attachment 2)
Anyone has any suggestions?
Best wishes,
Dou
Attachment:
ebout.png
Description: PNG image
Attachment:
outputFields.png
Description: PNG image
- 
        [Opal] Field Output Command,
        douguoliang, 03/04/2022
- 
            
            RE: [Opal] Field Output Command,
            Zhang Hui (PSI), 03/04/2022
- 
            
            Re: [Opal] Field Output Command,
            Chris Rogers, 03/04/2022
- Re: [Opal] Field Output Command, Calvo Portela, Pedro, 03/07/2022
 
 
 - 
            
            Re: [Opal] Field Output Command,
            Chris Rogers, 03/04/2022
 
 - 
            
            RE: [Opal] Field Output Command,
            Zhang Hui (PSI), 03/04/2022
 
Archive powered by MHonArc 2.6.19.